Chapter 7 Elevator application guidance Shenzhen Hpmont Technology Co., Ltd.
72 HD3L Series Controller User Manual
Table 7-2 Terminal MS run parameter
Ref. Code Function Value Remark
F00.05 Operating mode 2 Terminal MS control
F02.02 Retention time of start zero-speed 0.5s
Adjust according to the situation of
running contactor and brake at
motor start & stop.
F02.06 Retention time of stop zero-speed 0.5s
F03.00 Acc speed 0.700m/s
2
Set according to the elevator speed
and running effect.
F03.01 Start Acc jerk 0.350m/s
3
F03.02 End Acc jerk 0.600m/s
3
F03.03 Dec speed 0.700m/s
2
F03.04 Start Dec jerk 0.600m/s
3
F03.05 End Dec jerk 0.350m/s
3
F03.06 Inspection Acc speed 0.200m/s
2
F03.07 Inspection Dec speed 1.000m/s
2
F03.13 Stop Dec jerk 0.350 m/s
3
F05.00 Multi-speed 0 0
As actual value
F05.01 Multi-speed 1 Re-leveling speed
F05.02 Multi-speed 2 Creeping speed
F05.03 Multi-speed 3 Battery driven speed
F05.04 Multi-speed 4 Inspection speed
F05.05 Multi-speed 5 Normal low speed
F05.06 Multi-speed 6 Normal mid speed
F05.07 Multi-speed 7 Normal high speed
F12.01 DI1 function 1 Controller enabled (EN)
F12.02 DI2 function 2 UP
F12.03 DI3 function 3 DN
F12.04 DI4 function 4 MS1
F12.05 DI5 function 5 MS2
F12.06 DI6 function 6 MS3
F12.15 DO1 function 2 Controller is running
F12.16 DO2 function 3 Controller is at zero-speed running
F12.17 RLY1 function 14 Controller fault
F16.07 Multi-speed inspection 4 Multi-speed inspection selection