EasyManua.ls Logo

hpmont HD3L Series - Page 85

hpmont HD3L Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Elevator application guidance Shenzhen Hpmont Technology Co., Ltd.
74 HD3L Series Controller User Manual
Ref. Code Function Value Remark
F04.04
Corresponding value of line 1 max.
setting
100.0%
F04.05 Line 2 min. setting 0.0%
F04.06
Corresponding value of line 2 min.
setting
0.0%
F04.07 Line 2 max. setting 100.0%
F04.08
Corresponding value of line 2 max.
setting
100.0%
F06.00 Pre-torque selection 1 Analogue weighing feedback
F06.01 Up pre-torque bias 50.0%
Set according to actual situation
and debug according to running
effect.
F06.02 Down pre-torque bias 50.0%
F06.03 Up electrical pre-torque gain 1.000
F06.04 Up brake pre-torque gain 1.000
F06.05 Down electrical pre-torque gain 1.000
F06.06 Down brake pre-torque gain 1.000
F12.01 DI1 function 1 Controller enabled (EN)
F12.02 DI2 function 2 UP
F12.03 DI3 function 3 DN
F12.15 DO1 function 2 Controller is running
F12.16 DO2 function 3 Controller is at zero-speed running
F12.17 RLY1 function 14 Controller fault
F13.00 AI1 function 1 Speed setting
F13.01 AI2 function 2 Weighing signal
F13.04 / F13.07 AI1/ AI2 bias 0.0%
Adjust according to actual
situation
F13.05 / F13.08 AI1/ AI2 gain 1.00
F13.06 / F13.09 AI1/ AI2 filter time 0.05s