Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 87
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
1: Connects with common
terminal
d03.02 Output terminal status
Display in 16-bit binary:
Bit15 - Bit6 Unused
Bit5 - Bit2 correspond to RLY4 -
RLY1
Bit1 - Bit0 correspond to DO2 -
DO1
Positive logic: 0 stands for
invalid while 1 stands for valid
Negative logic: 0 stands for valid
while 1 stands for invalid
Actual *
d03.03 MODBUS status
0: Normal
1: Communication timeout
2: Incorrect data frame head
3: Incorrect data frame checking
4: Incorrect data frame content
Actual *
d03.04 Total time at power-on (hour) 0 - 65535 Actual *
d03.05 Total running time (hour) 0 - 65535 Actual *
d03.06 Running times 0 - 65535 Actual *
d03.07 Present fault 0 - 100 Actual *
F00: Basic Parameters, on pages 46 - 47
F00.00 Motor type 0: Asynchronous motor 0 1
×
F00.01 Motor control mode
0: V/f control
1: SVC control
1 1
×
F00.02 Rated speed of elevator 0.100 - 4.000m/s 1.500m/s 0.001m/s
×
F00.03
Max. output frequency of
HD3L
5.00 - 100.00Hz 50.00Hz 0.01Hz
×
F00.04
Mechanical parameters of
motor
10.0 - 6000.0 60.0 0.1
×
F00.05 Operating mode
0: Keypad control
1: Terminal analogue control
2: Terminal MS control
0 1
×
F00.06 M-key function
0: Unused
1: UP / DN switch
0 1
F00.07 Speed setting of keypad 0.000m/s - F00.02 1.500m/s 0.001m/s
F00.08 Run direction
0: The same as run command
1: Opposite to run command
0 1
×
F01: Protection of Parameters, on pages 47 - 48
F01.00 Users password 00000 - 65535 00000 1
F01.01 Menu mode
0: Full menu mode
1: Checking menu mode
(display parameters different
from factory setting only)
0 1