MINIKEY User Manual Change print settings
Page 42 of 66 HSA SYSTEMS
In user-managed buffer mode, give warning on screen/network / both / none, if a
sensor signal is seen when no images are stored in buffer.
Stop on blank print
In user-managed buffer mode, stop print if a sensor signal is seen when no images
are stored in buffer.
Start block distance and end block distance
The purpose of block distance is to prevent the sensor from being triggered twice. For
instance if the media is an envelope with a window, the sensor will "believe" the front
edge of the window to be the back edge of the media. Thus the back edge of the
window will trigger the sensor again.
If you are printing on medias of equal length, you can enter the media length as your
start block distance and set the end block distance to 0. However this is not possible if
you are printing on medias of various size. If that is the case, your start block distance
should be a little longer than your start distance. Set the end block distance to 1cm or
less.
Job Size
The number of prints to make for this job.
Job Count
The number of prints done of job size
Job printed count
Total sum of prints for the job
Line name
What you enter here will be displayed when you create an object with systemdata
content and select linename as your data.