1. Use a wire stripper to peel about 7 mm length of insulation coating off one end of the
cable.
NOTICE
Do not cut the metal conductor of the cable when peeling insulation coating.
2. Insert the bare wire into a wire hole.
3. Tighten the screw on the wire hole with a flat-head screwdriver to lock the cable.
Huawei AR500&AR530&AR550 series Industrial Switch
Routers
Hardware Installation and Maintenance Guide
5 Installing an AR550 Series Industrial Switching Router
Issue 05 (2015-12-01) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
117