Troubleshooting
2 Analyzing and Rectifying Faults
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Step 2 Check whether the URL mode on the IMS and the IAD is the same.
If no, run the sip soft-parameter support-telurl command on the IAD to adjust the
URL mode.
If yes, go to Step 3.
Step 3 Run the sip soft-parameter sip-user-phone off command on the IAD to delete the record
where the user name is set to the phone number.
Step 4 Check whether the fault is rectified.
If yes, the procedure ends.
If yes, go to Step 5.
Step 5 Contact Huawei technical support engineers.
----End
2.3.17 Two Cascaded IAD132E(T)s Cannot Ping Each Other
Symptom
Two cascaded IAD132E(T)s cannot ping each other.
Cause
The possible causes are as follows:
The two IADs are connected through a direct-connect cable, but the cable-check function
is not enabled.
The network is disconnected or the power supply is faulty.
IP addresses are not in the same network segment.
Solution
Step 1 Run the cable-check enable command on the upstream IAD.
The two IADs can be cascaded through a crossover cable. If a direct-connect cable is used, you must
enable the cable-check function on the upstream IAD.
Step 2 Check whether network port indicators are normal.
If no, check the network cable and power supply.
If yes, go to Step 3.
Step 3 Verify that the IP addresses are in the same network segment.
Step 4 Check whether the fault is rectified.
If yes, the procedure ends.
If no, go to Step 5.
Step 5 Contact Huawei technical support.
----End