Step 6 Check whether a PCIe card is installed.
l If yes, go to Step 7.
l If no, go to Step 8.
Step 7 Remove the PCIe card.
For details, see 3.11 Removing a PCIe Card.
Step 8 Take the spare part out of its ESD bag.
Step 9 Determine the position of the processor.
Figure 5-11 Positions of processors
Step 10 Install the processor on the carrier.
1. Take a processor carrier out of an ESD bag.
2. Aligning the notch in one edge of the processor with the protrusion on the processor
carrier, secure it.
Ensure that the processor corner with a triangle mark is in the corner of the processor
carrier with a notched triangle.
FusionServer Pro CH121 V5 Compute Node
User Guide
5 Optional Part Installation
Issue 06 (2019-08-10) Copyright © Huawei Technologies Co., Ltd. 104