EasyManua.ls Logo

Huawei FusionServer Pro CH121 V5 - Page 114

Huawei FusionServer Pro CH121 V5
181 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 5-14 Pasting patterns
2. Use a clean card or blade to smear the thermal compound over the entire center of the
CPU.
The thickness of the thermal compound is about that of a piece of ordinary paper. Ensure
that the thermal compound is evenly and fully coated.
Figure 5-15 Smeared thermal compound layer
Step 12 Install the processor carrier to the heat sink.
1. Aligning the processor corner with a triangle mark with the corner of the heat sink with a
notched triangle, buckle the processor carrier on the heat sink.
FusionServer Pro CH121 V5 Compute Node
User Guide
5 Optional Part Installation
Issue 06 (2019-08-10) Copyright © Huawei Technologies Co., Ltd. 106

Table of Contents

Related product manuals