The two memory ejectors are closed automatically after the memory module is firmly
seated.
NOTE
Do not touch the edge connector on a memory module with bare hands. Before installing a
memory module, ensure that the edge connector is not contaminated.
Figure 5-24 Installing a memory module
Step 11 Check whether a PCIe card is installed.
l If yes, go to Step 12.
l If no, go to Step 13.
Step 12 Install the PCIe card.
For details, see 3.12 Installing a PCIe Card.
Step 13 Install the air duct.
For details, see 3.8 Installing the Air Duct.
Step 14 Install the cover.
For details, see 3.6 Installing the Cover.
Step 15 Install the compute node.
For details, see 3.4 Installing a CH121 V5.
Step 16 Power on the compute node.
For details, see 3.2 Power-On Procedure.
Step 17 Check whether the memory module is replaced successfully.
1. Log in to the iBMC WebUI.
For details, see 12.2 Logging In to the iBMC WebUI.
2. Choose Information > System Info > Memory, and check the memory information.
FusionServer Pro CH121 V5 Compute Node
User Guide
5 Optional Part Installation
Issue 06 (2019-08-10) Copyright © Huawei Technologies Co., Ltd. 112