Connect the possible faulty optimizer to the PV string.
Set DC SWITCH to ON. If the inverter status is Shutdown: Command, choose
Maintenance > Inverter ON/OFF, and send a startup command. View alarm
information.
If no Low insulation resistance alarm is reported 1 minute after the DC
side is powered on, the fault is on the possible faulty PV module.
If the Low insulation resistance alarm is reported 1 minute after the DC
side is powered on, the fault is on the possible faulty optimizer.
Log in to the app, choose Maintenance > Inverter ON/OFF on the home
screen, and send a shutdown command. Set DC SWITCH to OFF, replace the
faulty component, and complete troubleshooting the insulation resistance
fault. Go to Step 2 and check rest of the PV strings one by one. Then, go to
Step 8.
Step 8 Set DC SWITCH to ON. If the inverter status is Shutdown: Command, choose
Maintenance > Inverter ON/OFF, and send a startup command.
----End
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual K Locating Insulation Resistance Faults
Issue 18 (2024-03-10) Copyright © Huawei Technologies Co., Ltd. 128

Table of Contents

Other manuals for Huawei SUN2000-30KTL-M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-30KTL-M3 and is the answer not in the manual?

Huawei SUN2000-30KTL-M3 Specifications

General IconGeneral
ModelSUN2000-30KTL-M3
Max. DC Input Voltage1100 V
Number of MPPTs3
Rated AC Output Power30000 W
Max. Output Current47.8 A
Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)< 3%
Max. Efficiency98.7%
European Weighted Efficiency98.4%
DC ConnectionMC4
Protection DegreeIP66
Cooling MethodNatural convection
MPPT Voltage Range200 V - 1000 V
Max. AC Output Power33000 W
Rated AC Voltage400 V
AC Voltage Range320 V - 480 V
DisplayLED Indicators
CommunicationRS485, WLAN
Operating Temperature Range-25°C to 60°C
Relative Humidity0% - 100%
Operating Altitude4000 m
Weight43 kg
Dimensions640 x 530 x 270 mm
Max. DC Input Power45000 Wp