I-CORE WIRING COMPARTMENT
AND
INTERIOR
1.
Battery Compartment
(9
-
volt
alkaline battery) - The alkaline battery (not included) keeps time during
power
outages. The user may also program the
controller without AC power.
2.
Battery Compartment (CR2032 3-
volt
lithium) - The lithium battery provides backup timekeeping during
power
outages and when the 9-volt
is
not
installed (location
is
on the back
of
the facepack).
3.
Release for Facepack -
Pull
on
the release tab and the facepack
can
be removed from the facepack frame.
4.
Ribbon Cable - Cable that transmits information between the facepack and the inner controller assembly.
5.
Slide
Lock
Bar for
Output
Modules - Sliding the Slide Lock Bar turns the controller's
power
on
or
off
. Permits the addition
or
removal
of
output
modules and locks the modules into place
in
the Power On position.
6.
Power Module - This module provides
power
to
the controller. This module must be
in
place
for
the controller
to
operate.
7.
Station Module(s) - The addition
of
6 station modules allows the ability
to
expand your I-Core from 6
to
30 stations (plastic cabinet) and 6
to
42
stations
(metal cabinet and plastic pedestal).
Each
station module corresponds
to
six station screw terminals.
8.
Power and Accessory Terminals - Connections
for
Power, Sensors, Pump/Master Valve, and
other
accessory connections.
9.
Station Terminals - Connections
for
station wires; only terminals with corresponding Station
Output
Modules will be active and recognized by the
controller.
10.
Communication Port - Connection
for
future
use
with Central Control Communications.
11
. Earth Ground
Lug
- For connection
of
earth ground
copper
wire (for surge protection only). Do
not
connect valve commons
or
the incoming service
ground wire.
12.
Transformer - A transformer
is
installed
in
the controller
to
supply 24VAC
power
to
the controller. Transformer allows
for
either 120VAC
or
230VAC
connections.
13.
AC Wiring Compartment (Junction Box) - For connection
of
120/230VAC
power
.
14
. Conduit Opening - 1
to
1
V2'
(25 mm
to
38 mm) for field wiring into controller.
15
.
SmartPort
~
- Integrated connector
for
ICR/SRR/ROAM receiver (on side
of
cabinet).
Ex
planation of
Sy
mb
ols
~
AC A Hazardous Vollage Present
A
Cons
ult
Doc
umentati
on
ltl
Do
ubl
e I
nsu
l
ated
3
4