Number Message Cause Action
69 Alarm! Mower switch-
ed off
The alarm was started because the
product was switched off.
Enter the PIN code to disable the
alarm.
70 Alarm! Mower stopped The alarm was started because the
product was stopped.
71 Alarm! Mower lifted The alarm was started because the
product was lifted.
72 Alarm! Mower tilted The alarm was started because the
product was tilted.
75 Connection changed The loop signal was successfully
changed.
No action.
76 Connection NOT
changed
Failed to change the loop signal. Try several times to create a new loop
signal. If the problem remains, replace
the main circuit board. Refer to
To cre-
ate a new loop signal
in the Operator's
manual and
To replace the main circuit
board on page 20
.
77 Connectivity problem These is a problem with the communi-
cation circuit board in the product.
Restart the product. It can be a tempo-
rary problem, try to restart again in 30
minutes. If the problem stays, examine
the communication circuit board and
replace if necessary. Refer to
To re-
place the communication circuit board
for GARDENA
®
products on page 22
.
78 Slipped The product has hit an obstacle and
stopped or the wheels cannot move on
the wet grass.
Free the product and rectify the reason
for the lack of drive. If it is due to wet
grass, wait until the lawn has dried be-
fore using the product.
The work area includes a steep slope. Check the maximum guaranteed slope.
Steeper slopes should be isolated.
The guide wire is not laid at an angle
on a slope.
Lay the guide wire at an angle across
the slope.
81 Safety function faulty The indicator lamp on the keypad is de-
fective.
Restart the product. Examine the key-
pad, the main circuit board and their
cabling. Replace if necessary. Refer to
To replace the keypad on page 25
,
To
replace the main circuit board on page
20
.
119 Zone generator prob-
lem
ZoneProtect problem
The battery of the ZoneProtect acces-
sory is low. The ZoneProtect accessory
does not operate when the battery is
empty. The product can cut in the stay-
out zone if you start the product before
you charge the ZoneProtect accessory.
Park the product and charge the Zone-
Protect accessory before you start the
product.
The temperature in the ZoneProtect ac-
cessory is a higher than the maximum
limit and is set to off.
Put the product in an area with protec-
tion from the sun. Let the temperature
of the ZoneProtect accessory decrease
before you start the product.
1413 - 003 - 17.01.2022 Troubleshooting - 39