EasyManua.ls Logo

Husqvarna Automower 115H - Advanced Installation Features

Husqvarna Automower 115H
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.8.1 Test: Lawn coverage
Note: The
Test: Lawn coverage
can only be used once
the product has calibrated the guide wire. In other
words, the product must have left the charging station
on at least one occasion, either in
Auto
mode or in
connection with the start-up sequence.
The
Test: Lawn coverage
function is used to test if
the product can follow the guide wire or the boundary
loop at the selected corridor width out from the charging
station.
The
Test: Lawn coverage
can also be used to measure
the distance from the charging station to a remote area.
The distance, stated in meters, is shown in the product
display when STOP is pressed. How to do the test is
described in the Operator's manual.
3.9 SensorControl/Lawn shield/LawnSense
Note: SensorControl for GARDENA
®
SILENO life and
smart SILENO life, LawnSense for Flymo
®
and Lawn
sheild for McCULLOCH
®
are the same function. This
function is not available for the Husqvarna
®
model.
When SensorControl/Lawn shield/LawnSense is
activated, the product automatically adjust its mowing
times based on how fast the grass grows. This is
decided by continuously measuring the blade disc
resistance and comparing that to a mean value. If the
resistance is higher than the mean value, the product
is allowed to work for a longer time, and the other way
around. It takes a full day of mowing before the mean
value can be calculated, and during this time it will not
affect the mowing time.
Note: The mean value will be reset if the product has
been switched off for more than 50 hours or if the
settings are reset.
The SensorControl/Lawn shield/LawnSense does not
make the product work more than the timer settings,
only less. The product will always perform at least one
mowing cycle per day, only after that the mowing time is
reduced by the SensorControl/Lawn shield/LawnSense.
3.10 Safe operation in slopes
The product adjusts its operation automatically based on
factors such as the slope and travel direction.
If the slope is too steep, the product moves rearwards
and turns to try to find a less steep slope. If after 2
attempts the product cannot find a less steep slope, it
stops and the display indicates that the stop is caused
by a steep incline.
Slopes that exceed the specified maximum inclination
can normally only be reached in very favourable
conditions. Accessibility on steeper slopes than
specified cannot be guaranteed.
3.11 New loop signal
In rare cases, there may be a reason to change the loop
signal. For example, if two nearby installations have the
same loop signal they can interfere with each other.
1. Select a new loop signal via the menu in the display.
Note: A new loop signal has to be generated when
the product returns to its ordinary charging station, for
example after service if a charging station other than the
customer’s has been used. Refer to
Actions on page
13
.
1413 - 003 - 17.01.2022 Product and installation - 7

Table of Contents

Related product manuals