3--7
17
Safety and accident prevention
H plant short---circuit protection by means of rapid fuses, earthing of all plant
parts connected with work as well as all foreseeabl e accidental contact; a
thermal---magnetic overload cutout switch shuts down the motor;
H protection from accidental start---up by a minimum voltage relay in case of
power failure.
Emergency d evices
In accordance with Standard CEI 204---1:
H Chapter 5 Section 6 Sub--section 1 Emergency stop device”: «the emergency
stop device immediately s tops all the dangerous and other functions of the ma-
chine»;
H chapter 6 Section 2 Sub--section 4 Point 7 ”Protective guards”: «the removal of
protective guards designed to prevent access to dangerous parts or zones causes the
machine to stop immediately; replacing the guards does not restart the functions,
which must be reset».
...Emergency devices applicable to the S20DSP:
1. Emergency stop: a non---return mushroom---head pushbutton, colour red on
yellow background, is located on the control panel of the machine. To release
the pushbutton, the actuator must be rotated 45˚. After the emergency situ-
ation has been resolved, the machine must be reset.
2. Automatic thermal---magnetic cutout switch with thermal---magnetic relay:
The machine’s automatic switch, positioned on the left---hand side of the
base, has two protective systems against the lack of voltage. In fact, if there is
a lack of voltage, it disconnects all electrical devices, blocking the machine
immediately and impedes the automatic restore of the voltage. The other
function is that of re---arming the circuit breaker relay, positioned to protect
from the overloads of current.
3. Pressure transducer for monitoring the blade tension: the machine stops im-
mediately if the blade breaks or the tensioner cylinder pressure drops.
4. Protect ive guard for blade: a coded key microswitch is operated if the blade
cover is accidentally or intentionally opened during the machine operating
cycle, immediately shutting down all functions.
1
2
3
4

Table of Contents