11-1: Warranty Information
11 - Warranty Information
To avoid misunderstandings which might occur between machine owners and the
manufacturer, we are listing causes of component failure that specically voids warranty
coverage. Such causes listed in this section shall constitute abuse or neglect.
BLOWER
• Failure to lubricate impellers daily with a HydraMaster-recommended lubricant, to
lubricate bearings, to maintain proper oil levels, or to use the correct oil grade and
viscosity as recommended in blower manual.
• Failure to properly maintain blower safeguard systems such as waste tank lter screen,
vacuum safety relief valve and waste tank automatic shut-off system.
• Allowing foam to pass through blower.
HIGH PRESSURE WATER PUMP
• Failure to maintain proper oil level as recommended in pump manual.
• Failure to change oil in pump at recommended intervals.
• Failure to protect pump against freezing.
• Failure to maintain pump protection shut-off system.
• Failure to use water softener in hard water areas.
• Use of improper chemicals.
RECOVERY TANK
• Failure to properly maintain ltering devices in tank.
• Failure to clean tank as recommended by manufacturer.
• Failure to maintain vacuum safety release in tank.
• Use of improper chemicals.
CHEMICAL SYSTEM
• Use of improper chemical.
• Failure to use water softener in hard water area.
• Operating machine without proper chemical lter screen.
• Failure to protect against freezing.
CONTROL PANEL
• Failure to protect owmeter and water pressure gauge against freezing.

Table of Contents

HydraMaster GTXR+ - Warranty Information