Page 11-4 MAXX 450D/470D/Diesel
HydraMaster Corporation
1/18/00
DE-SCALING ( cont.)
Attach one section of female/female solution hose to the outgoing solution fitting on
the front of the machine and the other end to the garden hose and recirculation fitting
combination that is attached to the front of the machine (or as many sections as you
want, if you wish to de-scale your hoses).
Start the machine and allow it to run for three to five minutes. Depress the freeze
guard button and hold for 30 seconds. Do not leave the T.M. DeScaler solution in the
system. Flush the system with clean water and turn the machine “OFF”.
OVERALL MACHINE MAINTENANCE
Maintaining the original appearance of your unit is important for two reasons:
1. It represents a big dollar investment for your cleaning business and its
appearance should reflect that fact. A dirty machine is not professional.
2. Maintenance, troubleshooting, and repair is much easier to accomplish
on a clean, well maintained unit. Regular cleaning of the machine offers you
an opportunity to visually inspect all facets of the machine and spot potential
problems before they occur.
The following maintenance is recommended by the manufacturer at the frequency
indicated.
AFTER EACH JOB
1. Check recovery tank, stainless steel filter and filter bag as required.
DAILY
1. Wipe machine down thoroughly with a damp cloth.
2. Flush recovery tank out thoroughly.
3. Empty filter bag and inspect for rips, tears, etc. Replace as needed.
4. Remove, thoroughly clean and reinstall stainless steel filter screen in
recovery tank.
5. Inspect and clean vacuum slot on cleaning wand.