Pilot arc current levels
The pilot arc current level will change depending on the chosen process and arc current level. See table below.
Plasma Gas
30 amps 45 amps 70 amps 80 amps 130 amps
O2 20 20 30
N2 20 25 35
H35 35
F5 20 25
Air 25 35
Plasma Gas
30 amps 45 amps 70 amps 80 amps 130 amps
O2 10 10 15
N2 10 10 15
H35 15
F5 10 10
Air 10 15