46 Powermax30 AIR Operator Manual 808840
4 Operation
Understand duty-cycle limitations
The duty cycle is the percentage of time out of 10 minutes that a plasma arc can remain on when operating at an ambient
temperature of 40° C (104° F).
35% duty cycle at 240 V / 30 A: With input power of 240 V and the output current set to 30 A, the arc can remain
on for 3.5 minutes out of 10 minutes without causing the unit to overheat.
20% duty cycle at 120 V / 30 A*: With input power of 120 V and the output current set to 30 A, the arc can
remain on for 2.0 minutes out of 10 minutes without causing the unit to overheat.
* Although the duty cycle is rated for 30 A output, the recommended output current for 120 V circuits is 20 A or less. Operating the
system at 30 A on 120 V input can result in frequent tripped circuit breakers.
When you exceed the duty cycle and the system overheats, one of the following conditions occurs:
The temperature LED illuminates, the arc shuts off, and the cooling fan continues to run. To resume cutting, wait for
the temperature LED to extinguish.
The internal compressor LED and the temperature LED both illuminate. Allow the power supply to cool for 4 minutes
before using it again. If the problem persists, see Internal compressor LED faults on page 58 for more
troubleshooting tips.
When either condition occurs, leave the system on to allow the fan to cool the power
supply. The fan runs for 7 minutes after postflow.
Stretching the arc for prolonged periods while cutting can reduce the duty cycle. Stretching the arc requires the power
supply to generate a higher voltage output, which can cause it to run hotter and overheat more quickly.

Table of Contents

Other manuals for Hypertherm Powermax30 AIR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax30 AIR and is the answer not in the manual?

Hypertherm Powermax30 AIR Specifications

General IconGeneral
Built-in Air CompressorYes
Output Voltage83 VDC
Input Voltage120-240 V
Current Output15–30 A
Cutting ThicknessUp to 10 mm (3/8 in) recommended cut
Gas SupplyBuilt-in air compressor
Operating Temperature-10°C to +40°C (+14°F to +104°F)