EasyManuals Logo

Hypertherm Powermax45 XP Field Service Bulletin

Hypertherm Powermax45 XP
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Machine Interface Receptacle with Voltage Divider Board
6 809940 Field Service Bulletin Powermax45 XP
5. Remove the 2 plastic pins that attach the component barrier to the power PCB.
6. Lift the component barrier off of the plasma power supply.
7. Disconnect the front and rear panels. Use a blade screwdriver to push in the 2 tabs at the
bottom of each of the panels until the panels disconnect from the base.
5
6
6
5

Other manuals for Hypertherm Powermax45 XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax45 XP and is the answer not in the manual?

Hypertherm Powermax45 XP Specifications

General IconGeneral
Output Current10-45 A
Gas SupplyClean, dry, oil-free air or nitrogen
Torch StyleHandheld or mechanized
Input Voltage50/60 Hz
Cutting Thickness12 mm (1/2")
Cutting Capacity16 mm (5/8 in)
Recommended Gas Inlet Flow Rate/Pressure6.2 bar