EasyManua.ls Logo

IBM 1 Series - Interrupt Presentation; Status after Power Transitions and Resets

IBM 1 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interrupt
Presentation
CC3
Device
End—Reported
when
the
timer
has
decremented
one
more
than
the
specified
number
of
time
intervals
(underflow).
Also
reported
when
‘external
gate’
has
been
enabled
and
the
timer
detects
an
underflow
prior
to
the
end
of
one
complete
external
gate
cycle.
CC4
Attention—Reported
only
when
an
external
gate
cycle
has
been
completed
prior
to
a
timer
underflow;
‘run
state’
is
reset.
CC6
Attention
and
Exception—Reported
if
the
external
gate
cycle
has
been
completed
and
an
overrun
condition
is
present
in
the
timer;
‘run
state’
is
reset
(see
CC2).
CC7
Attention
and
Device
End—Reported
when
a
timer
has
underflowed
prior
to,
or
at
the
same
time
as,
the
completion
of
an
external
gate
cycle;
‘run
state’
is
reset.
The
timers
are
prepared
together
and
function
as
one
preparable
source.
Neither
timer
should
be
started
unless
the
I-bit
is
on.
After
the
timers
start,
they
post
the
first
device-end
interrupt
in
a
time
interval
corresponding
to
the
specified
count
up
to
a
maximum
of
one
more
count.
For
example,
if
a
count
of
hex
0003
is
loaded
(3
counts),
the
actual
time
to
the
first
device-end
interrupt
ranges
from
3 to
4
times
the
selected
time
base.
This
is
because
of
the
asynchronous
nature
of
the
internal
free-running
oscillator
or
external-pulse
train,
with
respect
to
the
program
setting
of
‘run
state’
or
the
activation
of
‘external
gate.’
This
uncertainty
must
be
taken
into
account
only
once
each
time
a
timer
is
started.
There
is
also
an
uncertainty
associated
with
the
value
of the
timers
when
measuring
the
duration
of
‘external
gate’
in
pulse-duration
applications.
This
is
because
of
the
asynchronous
nature
of
the
‘external
gate’
deactivation,
with
respect
to
the
internal
clock
or
external
pulse
train.
This
uncertainty
is
the
time
corresponding
to
+1
count
in
the
timer
value
after
it
is
stopped.
Pulse-averaging
applications
that
use
a
known
fixed-time
of
‘external
gate’
activation
and
random
pulses
on
the
‘customer
clock’
input
must
also
take
into
account
a
+1
count
uncertainty
in
the
timer
value
after
it
is
stopped
by
the
deactivation
of
‘external
gate.’
Status
After
Power
Transitions
and
Resets
When
a
machine
check
occurs,
or
when
a
Halt
I/O
or
Device
Reset
command
is
executed,
the
timers
are
stopped,
‘run
state’
is
reset,
the
mode
register
is
reset,
and any
pending
interrupt
requests
are
reset.
The
prepare
field,
including
the
I-bit,
and
the
value
in
the
timers
are
not
reset.
When
a
system
reset
occurs,
both
timers
are
stopped,
‘run
state’
is
reset,
and
the
mode
registers
are
reset.
The
values
held
in
the
timers
and
auto-load
registers
are
not
reset.
The
prepare
field,
including
the
I-bit,
is
reset.
When
a
power-on
reset
occurs,
all
resets
caused
by
system
reset
occur;
in
addition,
the
timers
are
reset
to
their
maximum
value
(that
is,
all
1’s),
and
the
auto-load
registers
are
set
to
their
maximum
value.
Timer
Feature
3-9

Table of Contents

Related product manuals