Notes:
1. You can only monitor storage subsystems that are within the management
domain of the storage-management software.
2. If you have not installed the DS4000 Storage Manager Event Monitor service as
part of the storage-management software installation, the DS4000 Storage
Manager Enterprise Management window must remain open. (If you close the
window, you will not receive any alert notifications from the managed storage
subsystems.)
For more information, see the Enterprise Management online Help.
Important: Refer to the IBM System Storage DS4000 Storage Manager 9.16
Installation and Support Guide for the appropriate operating system for
instructions on how to install the DS4000 Storage Manager 9.16 host
software.
In addition, to download the latest version of the DS4000 Storage
Manager host software, the DS4800 Storage Subsystem controller
firmware and NVSRAM, and the latest DS4000 ESM firmware, go to
the following Web site:
www.ibm.com/servers/storage/support/disk/
Note: The version of controller firmware determines which version of the DS4000
Storage Manager interface is displayed. For example, the interface for
DS4000 Storage Manager version 9.12 subsystem management would be
displayed when managing a DS4800 Storage Subsystem with controller
version 06.12.xx.xx installed, even if the installed version of the DS4000
Storage Manager client code is actually 9.16.
The DS4000 Storage Manager client provides the best way to diagnose and repair
storage-server failures. The software can help you:
v Determine the nature of the failure
v Locate the failed component
v Determine the recovery procedures to repair the failure
Although
the storage subsystem has Needs Attention LEDs, these LEDs do not
necessarily indicate which component has failed or needs to be replaced, or which
type of recovery procedure you must perform. In some cases (such as in the case
of a hard disk drive exceeding its PFAs), the Needs Attention LED does not turn on.
Only the DS4000 Storage Manager client can detect the failure.
For example, the recovery procedure for a Predictive Failure Analysis
®
(PFA) flag
(impending drive failure) on a drive varies depending on the drive status (hot spare,
unassigned, RAID level, current logical drive status, and so on). Depending on the
circumstances, a PFA flag on a drive can indicate a high risk of data loss (if the
drive is in a RAID 0 volume) or a minimal risk (if the drive is unassigned). Only the
DS4000 Storage Manager client can identify the risk level and provide the
necessary recovery procedures.
Note: For PFA flags, the General-system-error LED and Drive Needs Attention
LEDs do not turn on, so checking the LEDs will not notify you of the failure,
even if the risk of data loss is high.
108 IBM System Storage DS4800 Storage Subsystem: Installation, User’s, and Maintenance Guide

Table of Contents

Other manuals for IBM DS4800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM DS4800 and is the answer not in the manual?

IBM DS4800 Specifications

General IconGeneral
BrandIBM
ModelDS4800
CategoryStorage
LanguageEnglish

Related product manuals