184 IBM NeXtScale System Planning and Implementation Guide
Table 7-2 Power supply unit table
Table 7-3 System fan status table
Column Description
Status Possible values:
򐂰 Present: Power supply installed
򐂰 No Present: No power supply installed
򐂰 Fault: Power supply in faulty condition
Ratings Display the DC power output rating of the power supply
AC-IN Display the power AC input voltage rating
EPOW
a
a. For more information about Early Power Off Warning (EPOW) and Throttle, see
3.8, “Power management” on page 52.
Possible values:
򐂰 Assert: Power supply is in AC lost condition
򐂰 Normal: Power supply is in healthy, operating condition
Throttle
a
Possible values:
򐂰 Assert: Power supply is in over-current condition
򐂰 Normal: Power supply is in healthy, operating condition
DC-PG Power supply DC power status. Possible values:
򐂰 No: Power supply is not providing the required DC power
򐂰 Yes: Power supply is in healthy, operating condition
Column Description
Status Possible values:
򐂰 Present: fan installed
򐂰 No Present: no fan installed
Type Possible values:
򐂰 Low performance
򐂰 High performance (for future use)