Table 21. CA000000 to CA2799FF checkpoints (continued)
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code Description Action
CA00E1F4 End self-test sequence on one or more
boot devices; begin system management
services
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1F5 Build boot device list
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1F6 Determine boot device sequence
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1F7 No boot image located Go to “Boot problem resolution” on page 190.
CA00E1F8 Build boot device list for SCSD adapters.
(The location code of the SCSD adapter
being scanned is also displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1F9 Build boot device list for fibre-channel
adapters. (The location code of the SAN
adapter being scanned is also
displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1FA Building device list for SCSD adapters.
(The device ID and device LUN of the
device being scanned is also displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1FB Scan SCSD bus for attached devices
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1FC Build boot device list for SSA adapters.
(The location code of the SSA adapter
being scanned is also displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1FE Building device list for fibre-channel
(SAN) adapters. (The WWPN of the
SAN adapter being scanned is also
displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E1FF Build device list for fibre-channel (SAN)
adapters. (The LUN of the SAN adapter
being scanned is also displayed.)
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
Chapter 2. Diagnostics 115

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals