Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
651-613 D01 External cache ECC single-bit error. Go to “Performing the checkout procedure” on
page 184.
651-614 214 System bus time-out error. Go to “Performing the checkout procedure” on page 184.
651-615 292 Time-out error waiting for I/O. Go to “Performing the checkout procedure” on page
184.
651-619 Error log analysis indicates an error detected by the CPU. Use failing function codes
and the physical location codes from the diagnostic problem report screen to
determine the FRUs.
651-621 2C6 ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-623 2C6 Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-624 214 Memory control subsystem internal error. Go to “Performing the checkout
procedure” on page 184.
651-625 214 Memory address error (invalid address or access attempt). Go to “Performing the
checkout procedure” on page 184.
651-626 214 Memory data error (bad data going to memory). Go to “Performing the checkout
procedure” on page 184.
651-627 214 System bus time-out error. Go to “Performing the checkout procedure” on page 184.
651-628 210 System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-629 210 Error log analysis indicates an error detected by the memory controller. Go to
“Performing the checkout procedure” on page 184.
651-632 308 Internal device error. Go to “Performing the checkout procedure” on page 184.
651-639 210 Error log analysis indicates an error detected by the I/O. Using the problem
determination procedure, failing function codes, and the physical location codes
from the diagnostic problem report to determine the FRUs.
651-640 2D5 I/O general bus error. Go to “Performing the checkout procedure” on page 184.
651-641 2D6 Secondary I/O general bus error. Go to “Performing the checkout procedure” on
page 184.
651-642 2D3 Internal service processor memory error. Go to “Performing the checkout procedure”
on page 184.
651-643 2D3 Internal service processor firmware error. Go to “Performing the checkout
procedure” on page 184.
651-644 2D3 Other internal service processor hardware error. Go to “Performing the checkout
procedure” on page 184.
651-659 2CD ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-65A 2CE ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-65B 2CC ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-664 302 Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-665 303 Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-666 304 Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-669 2CD Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
132 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)