Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
651-734 292 Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 184.
651-735 292 Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 184.
651-736 292 Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 184.
651-740 2D3 Note: Ensure that the system IPLROS and service processor are at the latest
firmware level before removing any parts from the system.
651-741 2D3 Service processor error accessing special registers. Go to “Performing the checkout
procedure” on page 184.
651-742 2D3 Service processor reports unknown communication error. Go to “Performing the
checkout procedure” on page 184.
651-743 2D5 Service processor error accessing Vital Product Data EEPROM. Go to “Performing
the checkout procedure” on page 184.
651-745 2D9 Service processor error accessing power controller. Go to “Performing the checkout
procedure” on page 184.
651-746 2D4 Service processor error accessing fan sensor. Go to “Performing the checkout
procedure” on page 184.
651-747 2D5 Service processor error accessing thermal sensor. Go to “Performing the checkout
procedure” on page 184.
651-748 2E2 Service processor error accessing voltage sensor. Go to “Performing the checkout
procedure” on page 184.
651-750 2D4 Service processor detected NVRAM error. Go to “Performing the checkout
procedure” on page 184.
651-751 2D4 Service processor error accessing real-time clock/time-of-day clock. Go to
“Performing the checkout procedure” on page 184.
651-752 2D4 Service processor error accessing JTAG/COP controller/hardware. Go to
“Performing the checkout procedure” on page 184.
651-753 151 2D4 Service processor detects loss of voltage from the time-of-day clock backup battery.
Go to “Performing the checkout procedure” on page 184.
651-770 292 Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 184.
651-771 292 Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 184.
651-772 292 Intermediate or system bus time-out error. Go to “Performing the checkout
procedure” on page 184.
651-773 227 Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 184.
651-780 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
184.
651-781 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
184.
651-784 302 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
184.
651-785 303 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
184.
134 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)