Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
652-731 2C8 A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 184.
652-732 2C8 A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-733 2C8 292 A non-critical error has been detected: intermediate or system bus address parity
error. Schedule deferred maintenance. Go to “Performing the checkout procedure”
on page 184.
652-734 2C8 292 A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-735 2D2 292 A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-736 2D2 292 A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-770 2C8 292 A non-critical error has been detected: intermediate system bus address parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-771 2C8 292 A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-772 2D2 292 A non-critical error has been detected: intermediate or system bus time-out error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-773 227 A non-critical error has been detected: intermediate or system bus data parity error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-88x The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
652-89x The CEC or SPCN reported a non-critical error.
1. Schedule deferred maintenance.
2. Refer to the entry MAP in this system unit system service guide, with the 8-digit
error and location codes, for the necessary repair action.
3. If the 8-digit error and location codes were NOT reported, then run diagnostics
in problem determination mode and record and report the 8-digit error and
location codes for this SRN.
814-112 814 The NVRAM test failed. Go to “Performing the checkout procedure” on page 184.
814-113 221 The VPD test failed. Go to “Performing the checkout procedure” on page 184.
814-114 814 I/O Card NVRAM test failed. Go to “Performing the checkout procedure” on page
184.
Chapter 2. Diagnostics 137