Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
651-841 152 2E2 Sensor detected a voltage outside of the normal range. Go to “Performing the
checkout procedure” on page 184.
651-842 2E1 Sensor detected an abnormally high internal temperature. Make sure that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
651-90x Platform-specific error. Call your support center.
652-600 A non-critical error has been detected: uncorrectable memory or unsupported
memory. Schedule deferred maintenance. Examine the memory modules and
determine if they are supported types. If the modules are supported, then replace
the appropriate memory modules.
652-610 210 A non-critical error has been detected: CPU internal error. Schedule deferred
maintenance. Go to “Performing the checkout procedure” on page 184.
652-611 210 A non-critical error has been detected: CPU internal cache or cache controller error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-612 D01 A non-critical error has been detected: external cache parity or multi-bit ECC error.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-613 D01 A non-critical error has been detected: external cache ECC single-bit error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-623 2C6 A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-630 307 A non-critical error has been detected: I/O expansion bus parity error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-631 307 A non-critical error has been detected: I/O expansion bus time-out error. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-632 307 A non-critical error has been detected: I/O expansion bus connection failure.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-633 307 A non-critical error has been detected: I/O expansion unit not in an operating state.
Schedule deferred maintenance. Go to “Performing the checkout procedure” on page
184.
652-634 307 A non-critical error has been detected: internal device error. Schedule deferred
maintenance. Go to “Performing the checkout procedure” on page 184.
652-664 302 A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-665 303 A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-666 304 A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-669 2CD A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred G maintenance. Go to “Performing the checkout procedure” on page 184.
652-66A 2CE A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
652-66B 2CC A non-critical error has been detected: correctable error threshold exceeded. Schedule
deferred maintenance. Go to “Performing the checkout procedure” on page 184.
136 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)