Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
887-113 887 External loopback (twisted pair) parity test failed. Go to “Performing the checkout
procedure” on page 184.
887-114 887 Ethernet loopback (twisted pair) fairness test failed. Go to “Performing the checkout
procedure” on page 184.
887-115 887 External loopback (twisted pair) fairness and parity tests failed. Go to “Performing
the checkout procedure” on page 184.
887-116 887 Twisted pair wrap data failed. Go to “Performing the checkout procedure” on page
184.
887-117 887 Software device configuration fails. Go to “Performing the checkout procedure” on
page 184.
887-118 887 Device driver indicates a hardware problem. Go to “Performing the checkout
procedure” on page 184.
887-120 887 Device driver indicates a hardware problem. Go to “Performing the checkout
procedure” on page 184.
887-121 B08 Ethernet transceiver test failed. Go to “Performing the checkout procedure” on page
184.
887-122 B09 Ethernet 10 base-2 transceiver test failed. Go to “Performing the checkout procedure”
on page 184.
887-123 887 Internal loopback test failed. Go to “Performing the checkout procedure” on page
184.
887-124 887 Software error log indicates a hardware problem. Go to “Performing the checkout
procedure” on page 184.
887-125 887 Fuse test failed. Go to “Performing the checkout procedure” on page 184.
887-202 887 Vital Product Data test failed. Go to “Performing the checkout procedure” on page
184.
887-203 887 Vital Product Data test failed. Go to “Performing the checkout procedure” on page
184.
887-209 887 RJ-45 converter test failed. Go to “Performing the checkout procedure” on page 184.
887-304 887 Coprocessor internal test failed. Go to “Performing the checkout procedure” on page
184.
887-305 887 Internal loopback test failed. Go to “Performing the checkout procedure” on page
184.
887-306 887 Internal loopback test failed. Go to “Performing the checkout procedure” on page
184.
887-307 887 External loopback test failed. Go to “Performing the checkout procedure” on page
184.
887-319 887 Software device driver indicates a hardware failure. Go to “Performing the checkout
procedure” on page 184.
887-400 887 Fuse test failed. Go to “Performing the checkout procedure” on page 184.
887-401 887 Circuit breaker for Ethernet test failed. Go to “Performing the checkout procedure”
on page 184.
887-402 887 Ethernet 10 Base-2 transceiver test failed. Go to “Performing the checkout
procedure” on page 184.
887-403 887 Ethernet 10 Base-T transceiver test failed. Go to “Performing the checkout
procedure” on page 184.
887-405 887 Ethernet- network Rerun diagnostics in advanced mode for accurate problem
determination. Go to “Performing the checkout procedure” on page 184.