Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
950-2506 2506 221 Missing options resolution for 3Gb SAS Adapter card.
Try each of the following steps. After reseating, removing, or replacing a part, retry
the operation.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Reseat the 3Gb SAS Adapter card.
4. Replace the 3Gb SAS Adapter card.
5. Replace the system-board.
2506-102E 722 Out of alternate disk storage for storage. Go to “Performing the checkout procedure”
on page 184.
2506-3002 722 Addressed device failed to respond to selection. Go to “Performing the checkout
procedure” on page 184.
2506-3010 722 Disk returned wrong response to adapter. Go to “Performing the checkout
procedure” on page 184.
2506-3020 - Storage subsystem configuration error. Go to “Performing the checkout procedure”
on page 184.
2506-3100 - Controller detected device bus interface error. Go to “Performing the checkout
procedure” on page 184.
2506-3109 - Controller timed out a device command. Go to “Performing the checkout procedure”
on page 184.
2506-3110 - Device bus interface error. Go to “Performing the checkout procedure” on page 184.
2506-4010 - Configuration error, incorrect connection between cascaded enclosures. Go to
“Performing the checkout procedure” on page 184.
2506-4020 - Configuration error, connections exceed IOA design limits. Go to “Performing the
checkout procedure” on page 184.
2506-4030 - Configuration error, incorrect multipath connection. Go to “Performing the checkout
procedure” on page 184.
2506-4040 - Configuration error, incomplete multipath connection between controller and
enclosure detected. Go to “Performing the checkout procedure” on page 184.
2506-4041 - Configuration error, incomplete multipath connection between enclosure and device
detected. Go to “Performing the checkout procedure” on page 184.
2506-4050 - Attached enclosure does not support required multipath function. Go to “Performing
the checkout procedure” on page 184.
2506-4060 - Multipath redundancy level got worse. Go to “Performing the checkout procedure”
on page 184.
2506-4100 - Device bus fabric error. Go to “Performing the checkout procedure” on page 184.
2506-4101 - Temporary device bus fabric error. Go to “Performing the checkout procedure” on
page 184.
2506-4110 - Unsupported enclosure function detected. Go to “Performing the checkout
procedure” on page 184.
2506-4150 2506 PCI bus error detected by controller. Go to “Performing the checkout procedure” on
page 184.
2506-4160 2506 PCI bus error detected by controller. Go to “Performing the checkout procedure” on
page 184.
2506-7001 722 Temporary disk data error. Go to “Performing the checkout procedure” on page 184.
140 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)