Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2506-8008 BAT A permanent Cache Battery Pack failure occurred. Go to “Performing the checkout
procedure” on page 184.
2506-8009 BAT Impending Cache Battery Pack failure. Go to “Performing the checkout procedure”
on page 184.
2506-8150 2506 Controller failure. Go to “Performing the checkout procedure” on page 184.
2506-8157 2506 Temporary controller failure. Go to “Performing the checkout procedure” on page
184.
2506-9000 - Controller detected device error during configuration discovery. Go to “Performing
the checkout procedure” on page 184.
2506-9001 - Controller detected device error during configuration discovery. Go to “Performing
the checkout procedure” on page 184.
2506-9002 - Controller detected device error during configuration discovery. Go to “Performing
the checkout procedure” on page 184.
2506-9008 - Controller does not support function expected for one or more disks. Go to
“Performing the checkout procedure” on page 184.
2506-9010 - Cache data associated with attached disks cannot be found. Go to “Performing the
checkout procedure” on page 184.
2506-9011 - Cache data belongs to disks other than those attached. Go to “Performing the
checkout procedure” on page 184.
2506-9020 - Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
“Performing the checkout procedure” on page 184.
2506-9021 - Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
“Performing the checkout procedure” on page 184.
2506-9022 - Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
“Performing the checkout procedure” on page 184.
2506-9023 - One or more Disk Array members are not at required physical locations. Go to
“Performing the checkout procedure” on page 184.
2506-9024 - Physical location of Disk Array members conflict with another Disk Array. Go to
“Performing the checkout procedure” on page 184.
2506-9025 - Incompatible disk installed at degraded disk location in Disk Array. Go to
“Performing the checkout procedure” on page 184.
2506-9026 - Previously degraded disk in Disk Array not found at required physical location. Go
to “Performing the checkout procedure” on page 184.
2506-9027 - Disk Array is or would become degraded and parity data is out of synchronization.
Go to “Performing the checkout procedure” on page 184.
2506-9028 - Maximum number of functional Disk Arrays has been exceeded. Go to “Performing
the checkout procedure” on page 184.
2506-9029 - Maximum number of functional Disk Arrays disks has been exceeded. Go to
“Performing the checkout procedure” on page 184.
2506-9030 - Disk Array is degraded due to missing/failed disk. Go to “Performing the checkout
procedure” on page 184.
2506-9031 - Automatic reconstruction initiated for Disk Array. Go to “Performing the checkout
procedure” on page 184.
2506-9032 - Disk Array is degraded due to missing/failed disk. Go to “Performing the checkout
procedure” on page 184.
2506-9041 - Background Disk Array parity checking detected and corrected errors. Go to
“Performing the checkout procedure” on page 184.
Chapter 2. Diagnostics 141