Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2506-9042 - Background Disk Array parity checking detected and corrected errors on specified
disk. Go to “Performing the checkout procedure” on page 184.
2506-9050 - Required cache data can not be located for one or more disks. Go to “Performing the
checkout procedure” on page 184.
2506-9051 - Cache data exists for one or more missing/failed disks. Go to “Performing the
checkout procedure” on page 184.
2506-9052 - Cache data exists for one or more modified disks. Go to “Performing the checkout
procedure” on page 184.
2506-9054 - RAID controller resources not available due to previous problems. Go to
“Performing the checkout procedure” on page 184.
2506-9060 - One or more disk pairs are missing from a RAID-10 Disk Array. Go to “Performing
the checkout procedure” on page 184.
2506-9061 - One or more disks are missing from a RAID-0 Disk Array. Go to “Performing the
checkout procedure” on page 184.
2506-9062 - One or more disks are missing from a RAID-0 Disk Array. Go to “Performing the
checkout procedure” on page 184.
2506-9063 - Maximum number of functional Disk Arrays has been exceeded. Go to “Performing
the checkout procedure” on page 184.
2506-9073 - Multiple controllers connected in an invalid configuration. Go to “Performing the
checkout procedure” on page 184.
2506-9074 - Multiple controllers not capable of similar functions or controlling same set of
devices. Go to “Performing the checkout procedure” on page 184.
2506-9075 - Incomplete multipath connection between controller and remote controller. Go to
“Performing the checkout procedure” on page 184.
2506-9076 - Missing remote controller. Go to “Performing the checkout procedure” on page 184.
2506-9081 - Controller detected device error during internal media recovery. Go to “Performing
the checkout procedure” on page 184.
2506-9082 - Controller detected device error during internal media recovery. Go to “Performing
the checkout procedure” on page 184.
2506-9090 - Disk has been modified after last known status. Go to “Performing the checkout
procedure” on page 184.
2506-9091 - Incorrect disk configuration change has been detected. Go to “Performing the
checkout procedure” on page 184.
2506-9092 - Disk requires Format before use. Format the disk and retry the operation.
2506-FF3D 2506 Temporary controller failure. Retry the operation.
2506-FFF3 - Disk media format bad. Reformat the disk and retry the operation.
2506-FFF4 722 Device problem. Perform diagnostics on the device and retry the operation.
2506-FFF6 722 Device detected recoverable error. Retry the operation.
2506-FFFA 722 Temporary device bus error. Retry the operation.
2506-FFFE - Temporary device bus error. Retry the operation.
252B-101 252B Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board.
142 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)