Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
25C4-xxx 25C4 Generic reference for Broadcom adapter. Go to “Performing the checkout procedure”
on page 184.
25C4-201 25C4 Configuration error. Go to “Performing the checkout procedure” on page 184.
25C4-701 25C4 Permanent adapter failure. Go to “Performing the checkout procedure” on page 184.
25C4-601 25C4 Download firmware error. Go to “Performing the checkout procedure” on page 184.
25C4-602 25C4 EEPROM read error. Go to “Performing the checkout procedure” on page 184.
2604-xxx 2604 Generic reference for 4Gb Fibre Channel Adapter card. Go to “Performing the
checkout procedure” on page 184.
2604-102 2604 Reset Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre Channel
Adapter card.
2604-103 2604 Register Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel Adapter card.
2604-104 2604 SRAM Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel Adapter card.
2604-105 2604 Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel Adapter card.
2604-106 2604 Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card.
Replace the 4Gb Fibre Channel Adapter card.
2604-108 2604 221 Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go
to “Performing the checkout procedure” on page 184.
2604-110 2604 Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the
4Gb Fibre Channel Adapter card.
2604-201 2604 221 Configuration Register Test Failure for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 184.
2604-203 2604 PCI Wrap Test Failure for the Fibre Channel adapter card. Replace the 4Gb Fibre
Channel Adapter card.
2604-204 2604 221 DMA Test Failure for the Fibre Channel adapter card. Go to “Performing the
checkout procedure” on page 184.
2604-205 2604 221 Error on Read/Write Operation for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 184.
2604-701 2604 Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 184.
2604-703 2604 Error Log Analysis indicates that an unknown adapter error has occurred for the
Fibre Channel adapter card. Go to “Performing the checkout procedure” on page
184.
2604-704 2604 Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 184.
2604-705 2604 Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.