Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2604-706 2604 Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
2607-xxx 2607 Generic reference for 8Gb PCIe Fibre Channel Expansion Card. Go to “Performing
the checkout procedure” on page 184.
2607-102 2607 Reset Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-103 2607 Register Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-104 2607 SRAM Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe Fibre
Channel Expansion Card.
2607-105 2607 Internal Wrap Test failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
2607-106 2607 Gigabit Link Module (GLM) Wrap Test failure for the Fibre Channel adapter card.
Replace the 8Gb PCIe Fibre Channel Expansion Card.
2607-108 2607 221 Enhanced Error Handling Failure on the bus for the Fibre Channel adapter card. Go
to “Performing the checkout procedure” on page 184.
2607-110 2607 Enhanced Error Handling Failure on the Fibre Channel adapter card. Replace the
8Gb PCIe Fibre Channel Expansion Card.
2607-201 2607 221 Configuration Register Test Failure for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 184.
2607-203 2607 PCI Wrap Test Failure for the Fibre Channel adapter card. Replace the 8Gb PCIe
Fibre Channel Expansion Card.
2607-204 2607 221 DMA Test Failure for the Fibre Channel adapter card. Go to “Performing the
checkout procedure” on page 184.
2607-205 2607 221 Error on Read/Write Operation for the Fibre Channel adapter card. Go to
“Performing the checkout procedure” on page 184.
2607-701 2607 Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 184.
2607-703 2607 Error Log Analysis indicates that an unknown adapter error has occurred for the
Fibre Channel adapter card. Go to “Performing the checkout procedure” on page
184.
2607-704 2607 Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel
adapter card. Go to “Performing the checkout procedure” on page 184.
2607-705 2607 Error Log Analysis indicates that a parity error has been detected for the Fibre
Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data
being read or written incorrectly.
2607-706 2607 Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre
Channel adapter card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured
or the system is rebooted. This adapter must be replaced and not brought back
on-line. Failure to adhere to this action could result in data being read or written
incorrectly or in the loss of data.
Chapter 2. Diagnostics 147