Table 25. 101-711 through FFC-725 SRNs (continued)
SRN FFC Description and Action
2624-xxx 2624 Generic reference for 4X PCI-E DDR InfiniBand Host Channel Adapter -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-101 2624 Configuration failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-102 2624 Queue pair create failure - system-board and chassis assembly. Go to “Performing
the checkout procedure” on page 184.
2624-103 2624 Loop back test failure - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-201 cable
network
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
2624-301 cable
network
2624
Loop back test failure. Do the following steps one at a time, in order, and rerun the
test after each step:
1. Reseat the cable.
2. Replace the cable.
3. Verify that the network is functional.
4. Verify that the network switch is functional.
5. Go to “Performing the checkout procedure” on page 184.
2624-701 2624 Error Log Analysis indicates that this adapter has failed due to an internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-702 2624 Error Log Analysis indicates that this adapter has failed due to a failure with the
uplink interface used to connect this device to the host processor - system-board and
chassis assembly. Go to “Performing the checkout procedure” on page 184.
2624-703 2624 Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-704 2624 Error Log Analysis indicates that this adapter has failed due to a unrecoverable
internal parity error - system-board and chassis assembly. Go to “Performing the
checkout procedure” on page 184.
2624-705 2624 Error Log Analysis indicates that this adapter has failed due to a internal error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2624-706 2624 Error Log Analysis indicates that this adapter has failed due to a memory error -
system-board and chassis assembly. Go to “Performing the checkout procedure” on
page 184.
2640-121 2640 Physical volume hardware error. Go to “Performing the checkout procedure” on
page 184.
2640-131 2640 Smart status threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
2640-132 2640 Command timeouts threshold exceeded. Go to “Performing the checkout procedure”
on page 184.
2640-133 2640 Command timeout with error condition. Go to “Performing the checkout procedure”
on page 184.
148 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)