Table 14. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code Description Action
B200308C A problem occurred during the
startup of a partition.
The adapter type cannot be
determined.
Verify that a valid I/O Load Source is tagged.
B2003090 A problem occurred during the
startup of a partition.
Go to “Isolating firmware problems” on page 218.
B2003110 A problem occurred during the
startup of a partition.
Go to “Isolating firmware problems” on page 218.
B2003113 A problem occurred during the
startup of a partition.
Look for B7xx xxxx errors and resolve them.
B2003114 A problem occurred during the
startup of a partition.
Look for other errors and resolve them.
B2003120 Informational system log entry only. No corrective action is required.
B2003123 Informational system log entry only. No corrective action is required.
B2003125 During the startup of a partition, the
blade server firmware could not
obtain a segment of main storage
within the blade server to use for
managing the creation of a partition.
Check for server firmware updates; then, install the
updates if available.
B2003128 A problem occurred during the
startup of a partition. A return code
for an unexpected failure was
returned when attempting to query
the load source path.
Look for and resolve B700 69xx errors.
B2003130 A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
B2003135 A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
B2003140 A problem occurred during the
startup of a partition. This is a
configuration problem in the
partition.
Reconfigure the partition to include the intended load
source path.
B2003141 Informational system log entry only. No corrective action is required.
B2003142 Informational system log entry only. No corrective action is required.
B2003143 Informational system log entry only. No corrective action is required.
B2003144 Informational system log entry only. No corrective action is required.
B2003145 Informational system log entry only. No corrective action is required.
B2003200 Informational system log entry only. No corrective action is required.
B2004158 Informational system log entry only. No corrective action is required.
B2004400 A problem occurred during the
startup of a partition.
Check for server firmware updates; then, install the
updates if available.
Chapter 2. Diagnostics 33

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals