Table 14. B200xxxx Logical partition SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code Description Action
B2005106 A problem occurred during the
startup of a partition. There is not
enough space to contain the partition
main storage dump. The startup will
not continue.
Verify that there is sufficient memory available to start the
partition as it is configured. If there is already enough
memory, then go to “Isolating firmware problems” on
page 218.
B2005109 A problem occurred during the
startup of a partition. There was a
partition main storage dump
problem. The startup will not
continue.
Go to “Isolating firmware problems” on page 218.
B2005114 A problem occurred during the
startup of a partition. There is not
enough space to contain the partition
main storage dump. The startup will
not continue.
Go to “Isolating firmware problems” on page 218.
B2005115 A problem occurred during the
startup of a partition. There was an
error reading the partition main
storage dump from the partition
load source into main storage. The
startup will attempt to continue.
If the startup does not continue, look for and resolve
other errors.
B2005117 A problem occurred during the
startup of a partition. A partition
main storage dump has occurred but
cannot be written to the load source
device because a valid dump already
exists.
Use the Main Storage Dump Manager to rename or copy
the current main storage dump.
B2005121 A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The startup will not
continue.
Look for related errors in the "Product Activity Log" and
fix any problems found. Use virtual control panel
function 34 to retry the current Main Store Dump startup
while the partition is still in the failed state.
B2005122 Informational system log entry only. No corrective action is required.
B2005123 Informational system log entry only. No corrective action is required.
B2005135 A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
B2005137 A problem occurred during the
startup of a partition. There was an
error writing the partition main
storage dump to the partition load
source. The main store dump startup
will continue.
Look for other errors and resolve them.
34 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals