Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes Description Action
4705 System firmware failure. A problem
occurred when initializing, reading, or
using the system VPD. The Capacity on
Demand function is not available.
Restart the system.
4710 Informational system log entry only. No corrective action is required.
4714 Informational system log entry only. No corrective action is required.
4715 A problem occurred when initializing,
reading, or using system VPD.
Replace the management card, as described in
“Removing the tier 2 management card” on
page 255 and “Installing the tier 2 management
card” on page 256.
4750 Informational system log entry only. No corrective action is required.
4788 Informational system log entry only. No corrective action is required.
47CB Informational system log entry only. No corrective action is required.
5120 System firmware detected an error If the system is not exhibiting problematic
behavior, you can ignore this error. Otherwise,
go to “Isolating firmware problems” on page
218.
5121 System firmware detected a
programming problem for which a
platform dump may have been initiated.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to “Isolating firmware problems” on
page 218.
5122 An error occurred during a search for
the load source.
If the partition fails to startup, go to “Isolating
firmware problems” on page 218. Otherwise,
no corrective action is required.
5123 Informational system log entry only. No corrective action is required.
5190 Operating system error. The server
firmware detected a problem in an
operating system.
Check for error codes in the partition that is
reporting the error and take the appropriate
actions for those error codes.
5191 System firmware detected a virtual I/O
configuration error.
1. Use the Integrated Virtualization Manager
(IVM) or management console to verify or
reconfigure the invalid virtual I/O
configuration.
2. Check for server firmware updates; then,
install the updates if available.
5209 Informational system log entry only. No corrective action is required.
5219 Informational system log entry only. No corrective action is required.
5300 System firmware detected a failure
while partitioning resources. The
platform partitioning code encountered
an error.
Check the management-module event log for
error codes; then, take the actions associated
with those error codes.
5301 User intervention required. The system
detected a problem with the partition
configuration.
Use the Integrated Virtualization Manager
(IVM) or management console to reallocate the
system resources.
Chapter 2. Diagnostics 43

Table of Contents

Other manuals for IBM Power PS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power PS700 and is the answer not in the manual?

IBM Power PS700 Specifications

General IconGeneral
BrandIBM
ModelPower PS700
CategoryServer
LanguageEnglish

Related product manuals