Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA010002 Cannot get gateway IP address Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured;
then, retry the operation.
v The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA010003 Cannot get server hardware address Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured;
then, retry the operation.
v The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA010004 Bootp failed Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured;
then, retry the operation.
v The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
52 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)