EasyManuals Logo

IBM x3200 M3 7327 User Manual

IBM x3200 M3 7327
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #250 background imageLoading...
Page #250 background image
Use the backup copy of the server firmware until the primary copy is restored. After
the primary copy is restored, turn off the server; then, move the J6 jumper back to
the primary position (pins 1 and 2).
Using the integrated management module
The integrated management module (IMM) is a second generation of the functions
that were formerly provided by the baseboard management controller hardware. It
combines service processor functions, video controller, and (when an optional
virtual media key is installed) remote presence function in a single chip.
The IMM supports the following basic system management features:
v Environmental monitor with fan speed control for temperature, voltages, fan
failure, and power supply failure.
v Light path diagnostics LEDs indicators to report errors that occur with fans,
power supplies, microprocessor, hard disk drives, and system errors.
v DIMM error assistance. The Unified Extensible Firmware Interface (UEFI)
disables a failing DIMM that is detected during POST, and the IMM lights the
associated system error LED and the failing DIMM error LED.
v System event log (SEL).
v ROM-based IMM firmware flash updates.
v Auto Boot Failure Recovery (ABR).
v A virtual media key, which enables remote presence support (remote video,
remote keyboard/mouse, and remote storage).
v Automatic microprocessor disable on failure and restart in a two-microprocessor
configuration when one microprocessor signals an internal error.
v Nonmaskable interrupt (NMI) detection and reporting.
v Automatic Server Restart (ASR) when POST is not complete or the operating
system hangs and the operating system watchdog timer times-out. The IMM
might be configured to watch for the operating system watchdog timer and reboot
the system after a timeout, if the ASR feature is enabled. Otherwise, the IMM
allows the administrator to generate a nonmaskable interrupt (NMI) by pressing
an NMI button on the system board for an operating-system memory dump. ASR
is supported by IPMI.
v Intelligent Platform Management Interface (IPMI) Specification V2.0 and
Intelligent Platform Management Bus (IPMB) support.
v Serial port redirection over telnet or ssh.
v Serial over LAN (SOL).
v Active Energy Manager.
v Query power-supply input power.
v PECI 2 support.
v Power/reset control (power-on, hard and soft shutdown, hard and soft reset,
schedule power control).
v Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail).
v Operating-system failure blue screen capture.
v Command-line interface.
v Configuration save and restore.
v PCI configuration data.
v Boot sequence manipulation.
230 System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3200 M3 7327 and is the answer not in the manual?

IBM x3200 M3 7327 Specifications

General IconGeneral
Form FactorTower
Processor Sockets1
ChipsetIntel 3420
MemoryUp to 32 GB
Memory Slots4
StorageUp to 8 TB
Hard Drive Bays4
ProcessorIntel Xeon 3400 series
Memory TypeDDR3
RAID SupportRAID 0, 1, 10
NetworkDual Gigabit Ethernet
Expansion Slots4
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Drive Bays4 total (3.5-inch)

Related product manuals