v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Error code Description Action
0058007 DIMM population is unsupported.
1. Make sure the installed DIMMs follow the
population rules and sequence described in
“Installing a memory module” on page 169.
2. Reseat the DIMMs, and then restart the server.
3. Remove the lowest-numbered DIMM pair of those
that are identified and replace it with an identical
pair of known good DIMMs, then restart the
server.
4. Return the removed DIMMs, one pair at a time, to
their original connectors, restarting the server after
each pair, until a pair fails. Replace the DIMMs in
the failed pair with identical known good DIMMs,
restarting the server after each DIMM is installed.
Replace the failed DIMM. Repeat this step until
you have tested all removed DIMMs.
5. (Trained service technician only) Replace the
system board.
0058008 DIMM failed memory test.
1. Reseat the DIMMs, and then restart the server.
2. Replace the following components one at a time,
in the order shown, then restart the server after
each:
a. DIMM
b. (Trained service technician only) System
board
00580A4 Memory population changed. Information only. Memory has been added, moved, or
changed.
0068002 CMOS battery cleared.
1. Reseat the battery.
2. Clear the CMOS memory (see “System-board
jumpers and switches” on page 20).
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System
board
Chapter 3. Diagnostics 29