v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Error code Description Action
2018002 Option ROM resource allocation failure Informational message that some devices might not
be initialized.
1. If possible, rearrange the order of the adapters in
the PCI slots to change the load order of the
optional-device ROM code.
2. Run the Setup utility, select Startup Options, and
change the boot priority to change the load order
of the optional-device ROM code.
3. Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a. Select Startup Options -> Planar Ethernet
(PXE/DHCP) to disable the integrated
Ethernet controller ROM.
b. Select Advanced Functions -> PCI Bus
Control -> PCI ROM Control Execution to
disable the ROM of the adapter in the PCI
slots.
c. Select Devices and I/O Ports to disable any
of the integrated devices.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Each adapter
b. (Trained service technician only) System
board
3xx0007 (xx
can be 00 -
19)
Firmware fault detected, system halted
1. Recover the server firmware to the latest level
(see “Updating the firmware” on page 221).
2. Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the
default values (see “System-board jumpers and
switches” on page 20.
3. Remove any recently installed hardware.
3038003 Firmware corrupted
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
server firmware.
2. (Trained service technician only) Replace the
system board.
3048005 Booted secondary (backup) UEFI Image Information only. The backup switch was used to boot
the secondary bank.
Chapter 3. Diagnostics 31

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3200 M3 7327 and is the answer not in the manual?

IBM x3200 M3 7327 Specifications

General IconGeneral
Form FactorTower
Processor Sockets1
ChipsetIntel 3420
MemoryUp to 32 GB
Memory Slots4
StorageUp to 8 TB
Hard Drive Bays4
ProcessorIntel Xeon 3400 series
Memory TypeDDR3
RAID SupportRAID 0, 1, 10
NetworkDual Gigabit Ethernet
Expansion Slots4
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Drive Bays4 total (3.5-inch)