8.5-5
Fit the Vacuum Sealing Plate and secure using the two screws provided in the priming kit, as
illustrated below
PLEASE NOTE: The sealing plate should only be fitted when prompted on the screen of
CLARiTY™
Figure 8.5-7
Insert the power cable from the priming kit into the 15-way I/O connector located on the side
of the ICE Torus.
Switch on the ICE Torus printer and allow the ‘Boot Up’ sequence to complete.
When the ‘Home’ page of CLARiTY™ is displayed, navigate to:
Tools>Setup>Consumables>Prime Printhead