Symptom Remedy
HeatorCoolnotcomingon Verifywiringiscorrect,gentlypulloneachwiretoverifythereisagood
connectionatterminalblock.
Setpointsdonotdisplayallofthetime
Press ,
MENU
VIEW
, sixtimes,
displays
Checkforlowbatteryconditionorfaultyoutdoor/remotetemperaturesensor.
Remote Sensor
displays
Checkremotesensorstemperatureat
, ,
MENU
VIEW
, .
OVERRIDEdisplays Programscheduleisintemporaryoverride,itwillreturntoscheduleatthenext
transitiontime.
Condensationformingonwindows Decreasehumidicationsetting
Thermostatsaysthatthehumidieris
operatingbuthumidityhasnotrisen
Checkhumidierpadandreplaceifnecessary
Dehumidierisalwaysrunning Checktherelayconguration(Section22,Page17).
Theroomtemperatureismet,buttheair
conditionerisstilloperating
DehumidicationissettoCOOL-2.Thethermostatwillcontinuetoletthe
coolingsystemoperateuntilthecoolingtemperatureis3°Fbelowthesetpointor
whenthedehumidicationsetpointismet.
Ofine
! IfthethermostatorAPPshowsofine( !)formorethanafewminutes,unplug
thethermostatfromthewallplate,waitoneminute,thenplugthermostatback
intowallplate.