26
MONDAY
thru
SUNDAY
Factory Preprogramming
WAKE
6:00AM
LEAVE
8:00AM
RETURN
6:00PM
SLEEP
10:00PM
HEAT 70°F HEAT 62°F HEAT 70°F HEAT 62°F
COOL 78°F COOL 85°F COOL 78°F COOL 82°F
Thethermostatcomespre-programmedwiththefollowingschedule:
Symptom Remedy
Nodisplay Checkfor24VACatthermostat;displayisblankwhen24VACisnotpresent.
Timeanddayofweekmustberesetafterpowerlosswithnobatteriesinstalled.
Systemfandoesnotcomeonproperly Verifywiringiscorrect,checkheatsource(Gas/Electric)inConguration
(seeSection6,Page13).
Noresponsewithrstbuttonpress
Press
toactivatetouchicons.
Programscheduleactivatesatwrongtime Checktime(AM/PM)setonthermostat(seeSettingtheTime&Date,Page23).
Thermostatturnson/offtoofrequently
Adjusttemperaturedifferential(seeCongurationModeSetting,Section2,Page11).
Thermostatdoesnotfollowprogram
Verifythescheduleison
:checktime(AM/PM);checkifinprogram
override.
Fanrunscontinuously
Press
andsettoauto . iscontinuousrun.
Roomtemperatureisnotcorrect Calibratethermostat(seeCongurationModeSetting,Section13,Page15).
Ifremotesensorisused,checkS1andS2terminalconnections.
LOCKdisplayswhenanybuttonispressed
Thermostathasthebuttonlockoutfunctionactivated(seeLockout&Unlock
Feature,Page10).

ondisplayinsteadofroomtemp. CheckforabadconnectionatS1andS2terminals.
Troubleshooting