EasyManua.ls Logo

ICM Controls SC 2201 - Installing the Thermostat

ICM Controls SC 2201
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the Off position before removing the existing
thermostat.
IMPORTANT: Thermostatinstallationmustconformtolocalandnationalbuildingandelectricalcodesand
ordinances.
IMPORTANT: Thisthermostatiscompatiblewith100%lockoutsystems.Toresetthesystem,turnthermostat
toOffpositionforatleast60seconds.
Note:
Mountthethermostataboutvefeetabovetheoor.Donotmountthethermostatonanoutsidewall,
indirectsunlight,behindadoor,orinanareaaffectedbyaventorduct.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.
2. PutMode switchinOffposition.
3. PutFan switchinAutoposition.
4. Toremovecover,insertandtwistacoinorscrewdriver
intheslotsonthesidesofthethermostat.
5. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthroughthewireopening
inthebaseofthethermostat).
6. Marktheplacementofthemountingholes.
7. Setthermostatbaseandcoverawayfromworkingarea.
8. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
9. Useahammertotapsuppliedanchorsinmountingholes.
10. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughwireopening.
11. Usesuppliedscrewstomountthermostatbasetowall.
Cool Off Heat Emer Auto On
Mode Fan
To Install Thermostat

Related product manuals