9
Setting a New Temperature Differential
IMPORTANT: Thedefaulttemperaturedifferentialisfactorysetat1°F.Whenyourroomtemperaturevariesby1°F,the
thermostatturnsyoursystemon.Ifyounoticeyoursystemturningonandofftoofrequently,increase
thetemperaturedifferentialaccordingly.
Step 1: RemovecoverandpressResetbuttononce.
Step 2: Thedisplaywillshow
Thisisthetemperaturedifferentialsetting.
Step 3: Pressthe
or buttontoadjustthetemperaturedifferentialdownorup.
Thedisplaywillreturntotheroomtemperaturedisplayveseconds
afterthelastinput.Thenewtemperaturedifferentialsettingwillbe
saved.
Setting the Room Temperature (Setpoint Temperature)
Step 1: Pressthe or button;thecurrenttemperaturesetpointdisplays.
Step 2: Pressthe or buttonuntilthedesiredtemperaturesetpointdisplays.
Note:
Holdingdowneither
the or buttonwillscrollthe
temperaturedisplay.
Thenewtemperaturesettingisautomaticallysaved.After5seconds,thedisplayreturnsto
showingthecurrentroomtemperature.
Operation
Differential Setting °F °C
1 1°F 0.5°C
2 2°F 1.0°C
3 3°F 1.5°C