6
12. Insertstripped,labeledwiresinmatchingwireterminals.SeeWiringDiagramssectionofthismanual(Pages11-
24).
CAUTION!
:
Besureexposedportionofwiresdoesnottouchotherwires.
13. Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwireis
connectedtotheproperterminal.
14. Sealholeforwireswithnon-ammableputtyorinsulation.
15. Replacecoveronthermostatbysnappingitinplace.
16. Turnonpowertothesystematthemainservicepanel.
17. Testthermostatoperationasdescribedinthefollowingsection.
CAUTION!
:
Donotswitchsystemtocooliftheoutdoortemperatureisbelow50°F(10°C).Thiscandamage
theairconditioningsystemandmaycausepersonalinjury.
1. PuttheMode switchtoCoolposition.
2. Pressthe buttonuntilthetemperaturesettingisatleast3degreesbelowtheroom
temperature.Theairconditioningsystemandfanshouldturnonwithinafewseconds.
3. PuttheMode switchintheOffposition.Theairconditioningsystemshouldturnoff.
Thefanmayhaveadelay.
Note:
PressingtheResetbuttonwillbypassthe5-minuteanti-shortcycle
compressorprotection.
Cool Off Heat Emer
Cool Off Heat Emer
Mode
Mode
Testing the Thermostat