DMini scope screen
Spectrum scope screen
This function allows you to display the relative
strengths of signals around the center frequency. The
span can be set to ±12.5 kHz, ±25 kHz, ±50 kHz and
±100 kHz. Ideal for monitoring band conditions in an
instant.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [(F-1)SCOPE] to select the scope screen.
e Push [(F-1)SPAN] several times to select the scope
span.
r Push [(F-2)ATT] several times to activate an atten-
uator or turn the attenuator OFF.
10, 20 and 30 dB attenuators are available.
t Push [(F-3)MARKER] several times to select the
marker (sub readout or transmit frequency) or turn
the marker OFF.
•“TX MARKER” displays the marker at the transmit fre-
quency.
•“SUB MARKER” displays the marker at the sub readout
frequency.
y Push [(F-4)HOLD] to freeze the current spectrum
waveform.
“HOLD” appears while the function is in use.
u Push [EXIT/SET] to exit the scope screen.
If a strong signal is received, a ghost waveform may
appear. Push [(F-2)ATT] several times to activate
the spectrum scope attenuator in this case.
BW
BW
2.4k
2.4k
SFT
SFT
0
FIL2
FIL2
USB
USB
TX
TX
VFO
VFO
USB
USB
USB
USB
USB
USB
FIL2
FIL2
qr.qot.pp
qr.wpq.pp
14.100.00
14.100.00
14.100.00
14.100.00
1
1
VFO
VFO
SUB
SUB
MARKER
MARKER
ATT
ATT
10dB
10dB
HOLD
HOLD
Grid
Grid
2.5k
2.5k
10dB
10dB
+12.5k
+12.5k
-12.5k
-12.5k
SPECTRUM SCOPE
SPECTRUM SCOPE
ANT
ANT
1
METER
METER
Po
Po
ATT
ATT
OFF
OFF
VOX
VOX
OFF
OFF
COMP
COMP
OFF
OFF
WIDE
WIDE
AGC
AGC
MID
MID
P.AMP
P.AMP
1
HOLD
HOLD
SET
SET
SPAN
SPAN
ATT
ATT
MARKER
MARKER
qw:pp
12:00
Appears when the
marker is out of range.
Sub readout
or TX marker
Appears when the
marker is out of range.
[(F-3)MARKER]
[(F-2)ATT][(F-1)SPAN] [EXIT/SET]
[(F-4)HOLD]
[(F-5)SET]
5
55
FUNCTION FOR RECEIVE
This mini scope screen can be displayed with another
screen indication, such as set mode menu, decoder
screen, memory list screen, etc. simultaneously.
Push [MAIN/SUB•M.SCOPE] for 1 sec. to toggle
the mini scope indication ON and OFF.
**** RTTY Encode/Decode Monitor **** **** RTTY Encode/Decode Monitor ****
45bps BAUDOT Mark=2125Hz, Shift=170Hz 45bps BAUDOT Mark=2125Hz, Shift=170Hz
Max.62 Charascters x 8ch TX Memory Max.62 Charascters x 8ch TX Memory
If RTTY-FIL is OFF, Please turn ON. If RTTY-FIL is OFF, Please turn ON.
ANTANT
1
METERMETER
PoPo
P.AMPP.AMP
1
ATTATT
OFFOFF
AGCAGC
MIDMID
RTTYRTTY
FILFIL
ONON
1/41/4
OFFOFF
RTTY DECODERTTY DECODE
BWBW
350350
SFTSFT
0
VFOVFO
VFOVFO
wq≥qpp≥pp
14.100.0014.100.00
RTTY RTTY FIL2FIL2
SSBSSB
FIL2FIL2
TXTX
THRESHOLDTHRESHOLD 9 9
<MENU1><MENU1>
HLD/CLRHLD/CLR
TX MEMTX MEM
ADJADJ
WIDEWIDE
qw:pp
12:00
Grid
2.5k
10dB
+ 12.5k
- 12.5k
SPECTRUM SCOPE
[MAIN/SUB•M.SCOPE]