85
9
SCANS
■ Fine programmed scan/fine ∂F scan
Fine scan functions as programmed or ∂F scan, but
scan speed decreases when the squelch opens but
does not stop. The scanning tuning step shifts from
50 Hz to 10 Hz while the squelch opens.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [(F-5)SCAN] to select the scan screen.
e Set for programmed scan or ∂F scan as described
on previous page.
r Push [(F-1)PROG] or [(F-2)
∂∂
F] to start a scan.
• Decimal points blink while scanning.
t Push [(F-3)FINE] to start a fine scan.
•“FINE PROGRAM SCAN” or “FINE ∂F SCAN” ap-
pears.
y When the scan detects a signal, the scan speed
decreases but does not stop.
u Push [(F-1)PROG] or [(F-2)
∂∂
F] to stop the scan;
push [(F-3)FINE] to cancel the fine scan.
SFTSFT
0
FIL2FIL2
USBUSB
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
1
VFOVFO
BWBW
2.4k2.4k
SCANSCAN
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGC
MID
ATT
OFF
VOX
OFF
PROGPROG
∂
F FINEFINE
∂
F SPANF SPAN
SETSET
qw:pp
12:00
FINE PROGRAM SCANFINE PROGRAM SCAN
∂ F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz
SFTSFT
0
FIL2FIL2
USBUSB
TXTX
VFOVFO
USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpt.pp
14.100.0014.100.00
14.100.0014.100.00
1
1
VFOVFO
BWBW
2.4k2.4k
SCANSCAN
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
PROGPROG
∂
F FINEFINE
∂
F SPANF SPAN
SETSET
qw:pp
12:00
PROGRAM SCANPROGRAM SCAN
∂ F SpanSpan: ±±10kHz10kHz
ProgrammedProgrammed P1:P1:0.500.00MHz0.500.00MHz
scanscan edgesedges P2:P2: 29.999.99MHz29.999.99MHz
■ Memory scan operation
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Select memory mode.
e Push [(F-5)SCAN] to select the scan screen.
r Set [RF/SQL] open or closed.
• See p. 83 for scan condition.
•If the [RF/SQL] control function is set as “AUTO,” the
squelch is always open in SSB, CW and RTTY modes.
See pgs. 2, 30, 99 for details.
t Push [(F-1)MEMO] to start the memory scan.
• Decimal points blink while scanning.
y When the scan detects a signal, the scan stops,
pauses or ignores it depending on the resume set-
ting and the squelch condition.
u To cancel the scan, push [(F-1)MEMO].
2 or more memory channels must be programmed
for memory scan to start.
SFT
0
FIL2
USB
TX
VFO
USB
USB
USB
FIL2
qr.qot.pp
qr.wpt.pp
14.100.00
14.100.00
1
VFO
12
BW
2.4k
SCAN
ANT
1
COMP
OFF
WIDE
METER
Po
P.AMP
1
AGC
MID
ATT
OFF
VOX
OFF
MEMO
∂
F SELECT
∂
F SPAN
SET
qw:pp
12:00
MEMORY SCAN
∂ F Span
: ±
10kHz
Programmed
P1:
0.500.00MHz
scan
edges
P2:
29.999.99MHz
SFT
0
FIL2
USB
TX
VFO
USB
USB
USB
FIL2
qr.qot.pp
qr.wpt.pp
14.100.00
14.100.00
1
VFO
12
BW
2.4k
SCAN
ANT
1
COMP
OFF
WIDE
METER
Po
P.AMP
1
AGC
MID
ATT
OFF
VOX
OFF
MEMO
∂
F SELECT
∂
F SPAN
SET
qw:pp
12:00
∂ F Span
: ±
10kHz
Programmed
P1:
0.500.00MHz
scan
edges
P2:
29.999.99MHz