EasyManua.ls Logo

Icom IC-821H - Pll Adjustment; Frequency Adjustment

Icom IC-821H
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-2 PLL ADJUSTMENT
MEASUREMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
CONDITIONS VALUE
POINT
UNIT LOCATION UNIT ADJUST
REFERENCE 1
MAIN band Ireq.
: Any PLL Connect
an
RF Maximum level PLL
L42, L43
FREQUENCY
Preset
C1
07
to the center position.
voltmeter
(50
Q (More than
Receiving
impedance) to J3 pin
1.
-22
dBm)
2
MAIN band Ireq.
: Any Connect a Irequency 60.40000 MHz The trimmer
Receiving
counter to J3 pin
1.
capacitor
01
X1
VHF LOCK
1
MAIN band Ireq.
: 145.000 MHz PLL Connect a digital
3.0V
PLL
L7
VOLTAGE
Mode
:FM
multimeter to W11.
Receiving
2
MAIN band Ireq.
: 136.000 MHz 2.2 V
±0.5
V Verify
3
MAIN band Ireq.
: 174.000 MHz
6.2
V
±0.5
V
4
MAIN band Ireq.
: 145.000 MHz Connect
an
RF
-10dBm±3dB
Receiving
voltmeter (50 Q
impedance) to W11.
UHF
LOCK 1
MAIN band Ireq.
: 440.000 MHz PLL Connect a digital
4.0V
PLL C107
VOLTAGE
Mode
:FM
multi meter to W13.
Receiving
2
MAIN band Ireq.
: 420.000 MHz 1.6 V
±0.5
V Verily
3
MAIN band Ireq.
: 460.000 MHz 6.5 V
±0.5
V
4
MAIN band Ireq.
: 440.000 MHz
Connect
an
RF
-9
dBm
±3
dB
Receiving
voltmeter (50 Q
impedance) to W13.
5-3 FREQUENCY ADJUSTMENT
MEASUREMENT
,
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
CONDITIONS
VALUE
POINT
UNIT LOCATION
UNIT ADJUST
FM
TX-LO 1
MAIN band Ireq.
: Any
MAIN Connect a Irequency 10.85000 MHz
MAIN L18
FREQUENCY
Mode
:FM
counter to J27.
Transmitting
5-2

Related product manuals